-
1 voltage and phase, series/parallel circuits
Engineering: EУниверсальный русско-английский словарь > voltage and phase, series/parallel circuits
-
2 hase displacement between harmonious voltage components and current
Phase displacement between harmonious voltage components and current
60
Источник: ГОСТ Р 54130-2010: Качество электрической энергии. Термины и определения оригинал документа
Русско-английский словарь нормативно-технической терминологии > hase displacement between harmonious voltage components and current
-
3 напряжение и фаза в последовательных и параллельных цепях
Engineering: voltage and phase, series/parallel circuitsУниверсальный русско-английский словарь > напряжение и фаза в последовательных и параллельных цепях
-
4 напряжение линейного проводника относительно земли
напряжение линейного проводника относительно земли
Нрк. фазное напряжение относительно земли
Напряжение между линейным проводником и эталонной (относительной) землей в данной точке электрической цепи.
[ ГОСТ Р МЭК 60050-826-2009]
фазное напряжение относительно земли
Напряжение между линейным проводником и относительной землей в данной точке электрической цепи переменного тока.
[ ГОСТ Р МЭК 60050-195-2005]EN
line-to-earth voltage
line-to-ground voltage (US)
phase-to-earth voltage (deprecated)
voltage between a line conductor and reference earth at a given point of an electric circuit
Source: 195-05-03
[IEV number 826-11-08]FR
tension phase-terre, f
tension entre un conducteur de ligne et la terre de référence en un point donné d'un circuit électrique
Source: 195-05-03
[IEV number 826-11-08]Недопустимые, нерекомендуемые
Тематики
EN
DE
- Spannung Außenleiter - Erde, f
FR
- tension phase-terre, f
Русско-английский словарь нормативно-технической терминологии > напряжение линейного проводника относительно земли
-
5 функция обнаружения неправильного порядка чередования фаз напряжений
функция обнаружения неправильного порядка чередования фаз напряжений
-Параллельные тексты EN-RU
Both the voltage and current phase reversal function signals a fault when it detects that either the voltage or the current phases of a 3-phase motor are out of sequence, indicating a wiring error.
[Schneider Electric]Функция обнаружения неправильного порядка чередования фаз напряжений или токов переводит систему в аварийное состояние в случае, если обнаруживается что фазы напряжений или токов в проводниках, идущих к трехфазному электродвигателю, имеют неправильное чередование.
[Перевод Интент]
Тематики
- управление электродвигателями
- электротехника, основные понятия
EN
Русско-английский словарь нормативно-технической терминологии > функция обнаружения неправильного порядка чередования фаз напряжений
-
6 коэффициент мощности, не учитывающий высшие гармоники
- DPF
- displacement power factor
- displacement PF
- displacement P.F.
коэффициент мощности, не учитывающий высшие гармоники
-
[Интент]EN
displacement power factor
DPF
The displacement power factor is the power factor due to the phase shift between voltage and current at the fundamental line frequency. For sinusoidal (non-distorted) currents, the displacement power factor is the same as the apparent power factor.
[ http://www.ccontrolsys.com/w/Power_Factor]
displacement power factor
The ratio of real to apparent power for an inductive or capacitive linear load. (Displacement Power Factor= kilowatts60 Hz / kilovoltamps60 Hz, or FP (displacement) = kW60Hz / kVA60 Hz). For an inductive load the current lags the voltage and the power factor is called “lagging.” For a capacitive load the current leads the voltage and the power factor is called leading. In all cases if the current and voltage are in phase, the displacement power factor is unity (1). Displacement power factor ranges from unity to zero. The value of displacement power factor is also given by the cosine of the angle by which the current lags or leads the voltage. (see: Leading; Lagging; Linear Load; Power Factor.)
[ http://harmonicslimited.com/glossary/term/40]
displacement power factor
Displacement factor is equal to the power factor for linear loads with sinusoidal voltages and currents.
pf = cos (angle1 - angle2)
[ http://wiki.answers.com/Q/What_is_displacement_factor]Тематики
EN
- displacement P.F.
- displacement PF
- displacement power factor
- DPF
Русско-английский словарь нормативно-технической терминологии > коэффициент мощности, не учитывающий высшие гармоники
-
7 канал (тракт передачи измерительной информации)
канал
Индивидуальный тракт передачи измерительной информации в средстве измерений.
Примечание. "Канал" и "фаза" не одно и то же. Канал напряжения определяется разностью потенциалов между двумя проводниками. Понятие "фаза" относится к отдельному проводнику. В многофазных системах канал может быть между двумя фазами, или между фазой и нейтралью, или между фазой и землей, или между нейтралью и землей.
[ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]EN
channel
individual measurement path through an instrument
NOTE “Channel” and “phase” are not the same. A voltage channel is by definition the difference in potential between 2 conductors. Phase refers to a single conductor. On polyphase systems, a channel may be between 2 phases, or between a phase and neutral, or between a phase and earth, or between neutral and earth
[IEC 61000-4-30, ed. 2.0 (2008-10)]FR
voie (de mesure)
ensemble des dispositifs de mesure associés à une mesure individuelle
NOTE «Voies» et «phases» n’ont pas la même signification. Une voie de mesure correspond par définition à une différence de potentiel entre deux conducteurs. Une phase correspond à un simple conducteur. Dans les systèmes polyphasés, une voie de mesure peut être entre deux phases ou entre une phase et le neutre, ou entre une phase et la terre, ou entre le neutre et la terre.
[IEC 61000-4-30, ed. 2.0 (2008-10)]Тематики
EN
FR
Русско-английский словарь нормативно-технической терминологии > канал (тракт передачи измерительной информации)
-
8 функция обнаружения неправильного порядка чередования фаз токов
функция обнаружения неправильного порядка чередования фаз токов
-Параллельные тексты EN-RU
Both the voltage and current phase reversal function signals a fault when it detects that either the voltage or the current phases of a 3-phase motor are out of sequence, indicating a wiring error.
[Schneider Electric]Функция обнаружения неправильного порядка чередования фаз напряжений или токов переводит систему в аварийное состояние в случае, если обнаруживается что фазы напряжений или токов в проводниках, идущих к трехфазному электродвигателю, имеют неправильное чередование.
[Перевод Интент]
Тематики
- управление электродвигателями
- электротехника, основные понятия
EN
Русско-английский словарь нормативно-технической терминологии > функция обнаружения неправильного порядка чередования фаз токов
-
9 трансформатор напряжения
трансформатор напряжения
Трансформатор, в котором при нормальных условиях применения вторичное напряжение практически пропорционально первичному напряжению и при правильном включении сдвинуто относительно него по фазе на угол, близкий к нулю.
[ ГОСТ 18685-73]EN
voltage transformer
potential transformer
instrument transformer in which the secondary voltage, in normal conditions of use, is substantially proportional to the primary voltage and differs in phase from it by an angle which is approximately zero for an appropriate direction of the connections
[IEC 61968-2, ed. 2.0 (2011-03)]Тематики
Синонимы
- ТН
EN
Русско-английский словарь нормативно-технической терминологии > трансформатор напряжения
-
10 параллельная система ИБП
параллельная система ИБП
-
[Интент]Parallel Operation: The system shall have the option to install up to four (4) UPSs in parallel configuration for redundancy or capacity.
1. The parallel UPS system shall be of the same design, voltage, and frequency. UPS modules of different size ratings shall be permitted to be paralleled together for purposes of increased capacity or UPS module redundancy. The UPSs in the parallel configuration shall not be required to have the same load capacity rating.
2. Parallel Capacity: With N+0 system-level redundancy, up to 2MW of load can be supported by the system.
3. Parallel Redundancy: With N+1 system-level redundancy, up to 1.5MW of load can be supported by the system, and only the UPS being replaced must be isolated from the source (bypass operation is not required for the entire system during the UPS replacement procedure).
4. Output control: A load sharing circuit shall be incorporated into the parallel control circuits to ensure that under no-load conditions, no circulating current exists between modules. This feature also allows each UPS to share equal amounts of the total critical load bus. The output voltage, output frequency, output phase angle, and output impedance of each module shall operate in uniformity to ensure correct load sharing. This control function shall not require any additional footprint and shall be an integral function of each UPS. The static bypass switches shall be connected in parallel.
5. Parallel System Controls: To avoid single points of failure, the UPS system shall have no single dedicated control system designed to control the operation of the parallel UPS system. Control of and direction of parallel UPSs shall take place via a master/slave relationship, where the first UPS to receive logic power asserts itself as a master. In the event of a master failure, a slave UPS shall take the role of master and assume the responsibility of the previous master UPS. Regardless of which UPS is master or slave, user changes to the system status, such as request for bypass, can be done from any UPS connected to the bus and all UPS on the bus shall transfer in simultaneously.
6. Communication: Communication between modules shall be connected so that the removal of any single cable shall not jeopardize the integrity of the parallel communication system. Load sharing communications shall be galvanically isolated for purposes of fault tolerance between UPS modules. A UPS module's influence over load sharing shall be inhibited in any mode where the UPS inverter is not supporting its output bus. Transfers to and from bypass can be initiated from any online UPS in the system.
7. Display: Each UPS multi-color LCD touch screen user interface shall be capable of using an active touch screen mimic bus to show the quantity of UPS(s) connected to the critical bus, as well as the general status of each UPS, such as circuit breaker status information. Any touchscreen display shall support the configuration of the [entire parallel] system and shall provide event and alarm data for all UPSs in the parallel configuration. A Virtual Display Application shall be available for download to the customer’s computer and shalll support remote monitoring of a complete system with up to 4 UPSs in parallel.
8. Battery runtime: Each UPS must have its own battery solution. The battery solution for the entire system can be a combination of standard and third-party batteries, but each UPS must use only one battery solution – either standard or third-party batteries.
9. Switchgear: A custom switchgear option shall be required for parallel operation.
[Schneider Electric]Тематики
EN
Русско-английский словарь нормативно-технической терминологии > параллельная система ИБП
-
11 трехфазное устройство автоматического повторного включения с улавливанием синхронизма
трехфазное устройство автоматического повторного включения с улавливанием синхронизма
-EN
three-pole reclosing equipment with synchrocheck
three-phase reclosing equipment with synchrocheck
three-pole reclosing equipment with a check on voltage, frequency difference, and phase angle before closing the circuit-breaker
[IEV number 448-16-08]FR
réenclencheur tripolaire avec contrôle de synchronisme
réenclencheur tripolaire avec contrôle de la tension, de la différence de fréquence et de l'angle de phase avant fermeture du disjoncteur
[IEV number 448-16-08]3.3.10. На одиночных линиях с двусторонним питанием (при отсутствии шунтирующих связей) должен предусматриваться один из следующих видов трехфазного АПВ (или их комбинаций):
а) быстродействующее ТАПВ (БАПВ)
б) несинхронное ТАПВ (НАПВ);
в) ТАПВ с улавливанием синхронизма (ТАПВ УС).
[ПУЭ]Тематики
- высоковольтный аппарат, оборудование...
- электроснабжение в целом
Синонимы
EN
DE
FR
Русско-английский словарь нормативно-технической терминологии > трехфазное устройство автоматического повторного включения с улавливанием синхронизма
-
12 коэффициент мощности, учитывающий высшие гармоники
коэффициент мощности, учитывающий высшие гармоники
-
[Интент]EN
apparent power factor
APF
The apparent power factor (APF) is the ratio of real power to apparent power, including harmonics.
This includes all harmonics. Harmonic currents decrease the power factor, even when there is no phase angle between voltage and current.
[ http://www.ccontrolsys.com/w/Power_Factor]Тематики
EN
Русско-английский словарь нормативно-технической терминологии > коэффициент мощности, учитывающий высшие гармоники
-
13 небаланс напряжений
небаланс напряжений
Отличие по модулю значения хотя бы одного из фазных или линейных напряжений многофазной системы электроснабжения от значений напряжений других фаз.
[ ГОСТ 23875-88]EN
voltage unbalance
phenomenon due to the differences between voltage deviations on the various phases, at a point of a polyphase system, resulting from differences between the phase currents or geometrical asymmetry in the line
[IEV number 604-01-29]
voltage unbalance (imbalance)
in a polyphase system, a condition in which the magnitudes of the phase voltages or the phase angles between consecutive phases are not all equal (fundamental component)
NOTE In three phase systems, the degree of inequality is usually expressed as the ratio of the negative and zero sequence components to the positive sequence component. In this technical report, voltage unbalance is considered in relation to three-phase systems and negative sequence only
[IEC 61000-3-13, ed. 1.0 (2008-02)]
voltage unbalance
condition in a polyphase system in which the r.m.s. values of the line voltages (fundamental component), and/or the phase angles between consecutive line voltages, are not all equal
NOTE 1 The degree of the inequality is usually expressed as the ratios of the negative- and zero-sequence components to the positive-sequence component.
NOTE 2 In this standard, voltage unbalance is considered in relation to 3-phase systems.
[IEC 61000-4-30, ed. 2.0 (2008-10)]FR
déséquilibre des tensions d'un réseau
phénomène résultant des différences de charge ou des dissymétries géométriques de lignes et qui provoque des différences entre les écarts de tension sur les diverses phases en un point d'un réseau polyphasé
[IEV number 604-01-29]
déséquilibre de tension
dans un réseau d’énergie électrique polyphasé, état dans lequel les valeurs efficaces des tensions entre conducteurs (composante fondamentale), et/ou les différences de phase entre conducteurs successifs, ne sont pas toutes égales
NOTE 1 Le taux de déséquilibre s’exprime habituellement par le rapport de la composante inverse ou homopolaire à la composante directe.
NOTE 2 Dans la présente norme, le déséquilibre de tension est relatif aux réseaux triphasés
[IEC 61000-4-30, ed. 2.0 (2008-10)]Параллельные тексты EN-RU
Voltage unbalance
Voltage unbalance on the most unbalanced phase, displayed as a percentage of Vavg.
[Schneider Electric]Небаланс напряжений
Самое значительное отличие по модулю значения одного из линейных напряжений, выраженное в процентах от среднего напряжения Vavg.
[Перевод Интент]
Недопустимые, нерекомендуемые
Тематики
EN
DE
FR
Смотри также
Русско-английский словарь нормативно-технической терминологии > небаланс напряжений
14 напряжение относительно земли
напряжение относительно земли
UO
а) в распределительных сетях с заземленной нейтралью - напряжение между фазным проводником и заземленной нейтралью;
б) во всех других распределительных сетях - напряжение между незаземленными фазными проводниками и землей, когда один из фазных проводников накоротко соединен с землей.
[ ГОСТ Р 61557-1-2006]EN
voltage against earth, Uo
a) in distribution systems with an earthed neutral point, the voltage between a phase conductor and the earthed neutral point;
b) in all other distribution systems, the voltage present between the remaining phase conductors and earth when one of the phase conductors is shorted to earth
[IEC 61557-1, ed. 2.0 (2007-01)]FR
tension par rapport à la terre, Uo
a) dans un réseau de distribution dont le point neutre est mis à la terre, la tension d’un conducteur de phase par rapport au point neutre mis à la terre;
b) dans les autres types de réseaux de distribution, la tension qui apparaît entre la terre et les phases restantes lorsque l’une des phases est mise à la terre
[IEC 61557-1, ed. 2.0 (2007-01)]Тематики
EN
FR
3.3 напряжение относительно земли (voltage against earth); U0:
a) в распределительных сетях с заземленной нейтралью: Напряжение между фазным проводником и заземленной нейтралью;
b) во всех других распределительных сетях: Напряжение между незаземленными фазными проводниками и землей, когда один из фазных проводников накоротко соединен с землей.
Источник: ГОСТ Р 54127-1-2010: Сети электрические распределительные низковольтные напряжением до 1000 В переменного тока и 1500 В постоянного тока. Электробезопасность. Аппаратура для испытания, измерения или контроля средств защиты. Часть 1. Общие требования оригинал документа
3.1.3 напряжение относительно земли (voltage against earth) U0:
а) в распределительных сетях с заземленной нейтралью - напряжение между фазным проводником и заземленной нейтралью;
б) во всех других распределительных сетях - напряжение между незаземленными фазными проводниками и землей, когда один из фазных проводников накоротко соединен с землей.
Источник: ГОСТ Р МЭК 61557-1-2005: Сети электрические распределительные низковольтные напряжением до 1000 В переменного тока и 1500 В постоянного тока. Электробезопасность. Аппаратура для испытания, измерения или контроля средств защиты. Часть 1. Общие требования оригинал документа
Русско-английский словарь нормативно-технической терминологии > напряжение относительно земли
15 несимметрия напряжений
несимметрия напряжений
Состояние системы энергоснабжения трехфазного переменного тока, в которой среднеквадратические значения основных составляющих междуфазных напряжений или углы сдвига фаз между основными составляющими междуфазных напряжений не равны между собой.
Примечания
1 Степень несимметрии обычно выражают отношением напряжений обратной и нулевой последовательностей к напряжению прямой последовательности.
2 В настоящем стандарте несимметрия напряжений рассматривается применительно только к трехфазным системам энергоснабжения.
[ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]EN
voltage unbalance
condition in a polyphase system in which the r.m.s. values of the line voltages (fundamental component), and/or the phase angles between consecutive line voltages, are not all equal
NOTE 1 The degree of the inequality is usually expressed as the ratios of the negative- and zero-sequence components to the positive-sequence component.
NOTE 2 In this standard, voltage unbalance is considered in relation to 3-phase systems.
[IEC 61000-4-30, ed. 2.0 (2008-10)]FR
déséquilibre de tension
dans un réseau d’énergie électrique polyphasé, état dans lequel les valeurs efficaces des tensions entre conducteurs (composante fondamentale), et/ou les différences de phase entre conducteurs successifs, ne sont pas toutes égales
NOTE 1 Le taux de déséquilibre s’exprime habituellement par le rapport de la composante inverse ou homopolaire à la composante directe.
NOTE 2 Dans la présente norme, le déséquilibre de tension est relatif aux réseaux triphasés.
[IEC 61000-4-30, ed. 2.0 (2008-10)]Тематики
EN
FR
3.34 несимметрия напряжений (voltage unbalance): Состояние системы энергоснабжения трехфазного переменного тока, в которой среднеквадратические значения основных составляющих междуфазных напряжений или углы сдвига фаз между основными составляющими междуфазных напряжений не равны между собой.
Примечания
1 Степень несимметрии обычно выражают отношением напряжений обратной и нулевой последовательностей к напряжению прямой последовательности.
2 В настоящем стандарте несимметрия напряжений рассматривается применительно только к трехфазным системам энергоснабжения.
3.35 установившееся отклонение напряжения: Разность между среднеквадратическим значением напряжения основной частоты в системе электроснабжения, определенным на установленном интервале времени, и номинальным значением напряжения.
3.36
Источник: ГОСТ Р 51317.4.30-2008: Электрическая энергия. Совместимость технических средств электромагнитная. Методы измерений показателей качества электрической энергии оригинал документа
Русско-английский словарь нормативно-технической терминологии > несимметрия напряжений
16 группа соединения трехфазной обмотки
группа соединения трехфазной обмотки
Угловое смещение между векторами, представляющими напряжения между нейтралью (реальной или воображаемой) и одноименными выводами двух обмоток. При этом напряжения прямой последовательности прикладывают к выводам обмотки высшего напряжения в алфавитном порядке (если они обозначены буквами) или в числовой последовательности (если они обозначены цифрами). Принято, что векторы напряжений вращаются против часовой стрелки
Примечание — Вектор обмотки высшего напряжения принят в качестве базисного; смещение вектора напряжения любой другой обмотки обычно выражают в часах, при этом время указывает вектор напряжения данной обмотки (аналогично часовой стрелке), когда вектор обмотки высшего напряжения показывает 12 ч (аналогично минутной стрелке); возрастающие числа указывают на увеличивающийся сдвиг фаз.
(МЭС 421-10-08).
[ ГОСТ 30830-2002]EN
phase displacement
phase difference (for a transformer)
the angular difference between the phasors representing the voltages between the neutral point (real or imaginary) and the corresponding terminals of two windings, a positive-sequence voltage system being applied to the high-voltage terminals, following each other in alphabetical sequence if they are lettered, or in numerical sequence if they are numbered. The phasors are assumed to rotate in a counter-clockwise sense
[IEV number 421-10-08]FR
déphasage (pour un transformateur)
écart angulaire entre les phaseurs représentant les tensions entre le point neutre (réel ou fictif) et les bornes homologues de deux enroulements lorsqu'un système de tension direct est appliqué aux bornes de l'enroulement à haute tension dans l'ordre de séquence alphabétique de ces bornes si elles sont repérées par des lettres, ou dans leur ordre de séquence numérique si elles sont repérées par des chiffres. Les phaseurs sont supposés tourner en sens inverse des aiguilles d'une horloge
[IEV number 421-10-08]Тематики
Классификация
>>>Обобщающие термины
EN
DE
FR
Русско-английский словарь нормативно-технической терминологии > группа соединения трехфазной обмотки
17 номинальное напряжение
номинальное напряжение
Напряжение, установленное изготовителем для прибора
[ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]
номинальное напряжение Uном, кВ
Номинальное междуфазное напряжение электрической сети, для работы в которой предназначены коммутационные аппараты.
[ ГОСТ Р 52726-2007]
номинальное напряжение
Un
Напряжение, применяемое для обозначения или идентификации системы электроснабжения.
[ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]EN
rated voltage
voltage assigned to the appliance by the manufacturer
[IEC 60335-1, ed. 4.0 (2001-05)]
rated voltage
quantity value assigned, generally by the manufacturer, for a specified operating condition of a machine
[IEC 60034-18-41, ed. 1.0 (2006-10)]
rated voltage
input or output supply voltage for which equipment is designed or specified
[IEC 88528-11, ed. 1.0 (2004-03)]
rated voltage
specified value of the voltage at the terminals of the machine when operating at a rating. If unidirectional, the voltage is the arithmetic mean of the recurring waveform and if alternating it is the root mean square value of the fundamental frequency component of the recurring waveform
NOTE - In the case of a machine with a protective resistor permanently in series, the resistor is considered as an integral part of the machine
[IEC 60349-1, ed. 1.0 (1999-11)]
rated voltage
the value of voltage assigned by the manufacturer to a component, device or equipment and to which operation and performance characteristics are referred
NOTE - Equipment may have more than one rated voltage value or may have a rated voltage range.
[IEC 62497-1, ed. 1.0 (2010-02)]
rated voltage
reference voltage for which the cable is designed, and which serves to define the electrical tests
NOTE 1 - The rated voltage is expressed by the combination of two values: Uo/U expressed in volts (V):
Uo being the r.m.s. value between any insulated conductor and "earth" (metal covering of the cable or the surrounding medium);
U being the r.m.s. value between any two phase conductors of a multicore cable or of a system of single-core cables.
In an alternating-current system, the rated voltage of a cable is at least equal to the nominal voltage of the system for which it is intended.
This condition applies both to the value Uo and to the value U.
In a direct current system, the nominal voltage of the system is not higher than 1,5 times the rated voltage of the cable.
NOTE 2 - The operating voltage of a system may permanently exceed the nominal voltage of such a system by 10 %. A cable can be used at a 10 % higher operating voltage than its rated voltage if the latter is at least equal to the nominal voltage of the system
[IEC 60245-1, ed. 4.0 (2003-12)]
rated voltage
highest allowable voltage between the conductors in a twin and multi conductor cable, or between one conductor and an electrical conductive screen, or between the two ends of a single core cable, or earth in unscreened cables
[IEC 60800, ed. 3.0 (2009-07)]
rated voltage
the r.m.s. line-to-line voltage under rated conditions
Primary side of input transformer: ULN
Converter input: UVN
Converter output: UaN
Motor voltage: UAN
[IEC 61800-4, ed. 1.0 (2002-09)]
rated voltage
input or output voltage (for three-phase supply, the phase-to-phase voltage) as declared by the manufacturer
[IEC 62040-1, ed. 1.0 (2008-06)]
nominal voltage, Un
voltage by which a system is designated or identified
[IEC 61000-4-30, ed. 2.0 (2008-10)]FR
tension assignée
tension attribuée à l'appareil par le fabricant
[IEC 60335-1, ed. 4.0 (2001-05)]
tension nominale
tension assignée, généraleme<>value of voltage assigned by the manufacturer, to a componentnt par le constructeur pour des conditions spécifiées de fonctionnement de la machine
[IEC 60034-18-41, ed. 1.0 (2006-10)]
tension assignée
tension spécifiée aux bornes de la machine quand celle-ci fonctionne au régime assigné. Dans le cas d'une tension redressée, sa valeur est égale à la valeur moyenne de l'onde périodique. Dans le cas d'une tension alternative, sa valeur est égale à la valeur efficace de la composante fondamentale de l'onde périodique
NOTE - Dans le cas d'une machine équipée d'une résistance de protection connectée en permanence en série, la résistance est considérée comme faisant partie intégrante de la machine
[IEC 60349-1, ed. 1.0 (1999-11)]
tension assignée
valeur de la tension, assignée par le constructeur à un composant, à un dispositif ou à un matériel, et à laquelle on se réfère pour le fonctionnement et pour les caractéristiques fonctionnelles
NOTE - Les matériels peuvent avoir plusieurs valeurs ou une plage de tensions assignées.
[IEC 62497-1, ed. 1.0 (2010-02)]
tension assignée
tension de référence pour laquelle le conducteur ou le câble est prévu et qui sert à définir les essais électriques
NOTE 1 - La tension assignée est exprimée par la combinaison de deux valeurs Uo /U, exprimées en volts (V):
Uo étant la valeur efficace entre l'âme d'un conducteur isolé quelconque et la «terre» (revêtement métallique du câble au milieu environnant);
U étant la valeur efficace entre les âmes conductrices de deux conducteurs de phase quelconques d'un câble multiconducteur ou d'un système de câbles monoconducteurs ou de conducteurs.
Dans un système à courant alternatif, la tension assignée d'un conducteur ou d’un câble est au moins égale à la tension nominale du système pour lequel il est prévu.
Cette condition s'applique à la fois à la valeur Uo et à la valeur U.
Dans un système à courant continu, la tension nominale admise du système n’est pas supérieure à 1,5 fois la tension assignée du conducteur ou du câble.
NOTE 2 - La tension de service d'un système peut en permanence dépasser la tension nominale dudit système de 10 %. Un conducteur ou un câble peut être utilisé à une tension de service supérieure de 10 % à sa tension assignée si cette dernière est au moins égale à la tension nominale du système
[IEC 60245-1, ed. 4.0 (2003-12)]
tension assignée
tension maximale admissible entre les âmes dans un câble ayant une paire ou multi conducteur ou entre une âme et un écran conducteur électrique ou avec la terre pour un câble non écranté ou encore entre les deux extrémités d’un câble à âme unique
[IEC 60800, ed. 3.0 (2009-07)]
tension assignée
valeur efficace de la tension de ligne (entre phases) dans les conditions assignées
Primaire du transformateur d’entrée: ULN
Entrée du convertisseur: UVN
Sortie du convertisseur: UaN
Moteur: UAN
[IEC 61800-4, ed. 1.0 (2002-09)]
tension assignée
tension d’alimentation d’entrée ou de sortie (dans le cas d’une alimentation triphasée, tension entre phases) déclarée par le constructeur
[IEC 62040-1, ed. 1.0 (2008-06)]
tension nominale, Un
tension par laquelle un réseau est désigné ou identifié
[IEC 61000-4-30, ed. 2.0 (2008-10)]Тематики
- аппарат, изделие, устройство...
- высоковольтный аппарат, оборудование...
- прибор электрический
- электроснабжение в целом
Синонимы
- Un
EN
FR
3.17 номинальное напряжение (rated voltage): Напряжение, установленное для выключателя изготовителем.
Источник: ГОСТ Р 51324.1-2005: Выключатели для бытовых и аналогичных стационарных электрических установок. Часть 1. Общие требования и методы испытаний оригинал документа
1.5.10 номинальное напряжение (rated voltage): Номинальное напряжение - это либо эффективное значение рабочего напряжения номинальной частоты, либо рабочее постоянное напряжение, которое можно длительно подавать на выводы конденсатора при любой температуре между нижней и верхней температурами категории. Это означает, что у конденсаторов, на которые распространяется настоящий стандарт, напряжение категории равно номинальному напряжению.
Источник: ГОСТ Р МЭК 60384-14-2004: Конденсаторы постоянной емкости для электронной аппаратуры. Часть 14. Групповые технические условия на конденсаторы постоянной емкости для подавления электромагнитных помех и соединения с питающими магистралями оригинал документа
3.2.1 номинальное напряжение (rated voltage): Напряжение, указанное изготовителем для этой машины, или напряжение между фазами (линейное) - при трехфазном питании.
Источник: ГОСТ Р МЭК 60745-1-2005: Машины ручные электрические. Безопасность и методы испытаний. Часть 1. Общие требования оригинал документа
3.25 номинальное напряжение (rated voltage): Напряжение, установленное изготовителем соединителей, которое указывается в стандартах или технических условиях.
Источник: ГОСТ Р 51322.1-2011: Соединители электрические штепсельные бытового и аналогичного назначения. Часть 1. Общие требования и методы испытаний оригинал документа
3.4 номинальное напряжение (rated voltage): Напряжение или диапазон напряжений, маркируемый на лампе.
Источник: ГОСТ Р 53881-2010: Лампы со встроенными пускорегулирующими аппаратами для общего освещения. Требования безопасности оригинал документа
1.3.2 номинальное напряжение (nominal voltage): Номинальное напряжение герметичного никель-кадмиевого аккумулятора, равное 1,2 В.
Источник: ГОСТ Р МЭК 60622-2010: Аккумуляторы и аккумуляторные батареи, содержащие щелочной и другие некислотные электролиты. Герметичные никель-кадмиевые призматические аккумуляторы оригинал документа
3.4 номинальное напряжение (nominal voltage): Подходящее приблизительное значение напряжения, используемое для идентификации напряжения аккумулятора или батареи.
Примечания
1. Номинальное напряжение литиевых аккумуляторов указано в таблице 1.
2. Номинальное напряжение батареи, состоящей из n соединенных последовательно аккумуляторов, равно номинальному напряжению отдельного аккумулятора, увеличенному в n раз.
Источник: ГОСТ Р МЭК 61960-2007: Аккумуляторы и аккумуляторные батареи, содержащие щелочной и другие некислотные электролиты. Аккумуляторы и аккумуляторные батареи литиевые для портативного применения оригинал документа
1.3.2 номинальное напряжение (nominal voltage): Номинальное напряжение открытого никель-кадмиевого аккумулятора с газовой рекомбинацией, равное 1,2 В.
Источник: ГОСТ Р МЭК 60623-2008: Аккумуляторы и аккумуляторные батареи, содержащие щелочной и другие некислотные электролиты. Аккумуляторы никель-кадмиевые открытые призматические оригинал документа
3.23 номинальное напряжение (rated voltage): Значение напряжения, на которое рассчитаны рабочие и эксплуатационные характеристики распределенных электронагревателей.
Источник: ГОСТ Р МЭК 60079-30-1-2009: Взрывоопасные среды. Резистивный распределенный электронагреватель. Часть 30-1. Общие технические требования и методы испытаний оригинал документа
1.5.9 номинальное напряжение (rated voltage): Напряжение или диапазон напряжения, заданное(ый) в соответствии с настоящим стандартом.
Примечание - Если в маркировке на лампе приведен диапазон напряжения, это значит, что возможна эксплуатация ламп при любом значении напряжения в пределах этого диапазона.
Источник: ГОСТ Р 52706-2007: Лампы накаливания вольфрамовые для бытового и аналогичного общего освещения. Эксплуатационные требования оригинал документа
1.2.1.1. номинальное напряжение (rated voltage): Указанное изготовителем напряжение источника сетевого электропитания (для трехфазного источника электропитания принимают линейное напряжение).
Источник: ГОСТ Р МЭК 60950-1-2009: Оборудование информационных технологий. Требования безопасности. Часть 1. Общие требования оригинал документа
1.2.1.1 номинальное напряжение (rated voltage): Указанное изготовителем напряжение источника сетевого электропитания (для трехфазного источника электропитания принимают линейное напряжение).
Источник: ГОСТ Р МЭК 60950-1-2005: Оборудование информационных технологий. Требования безопасности. Часть 1. Общие требования оригинал документа
3.37 номинальное напряжение (rated voltage): Значение напряжения для заданных условий эксплуатации.
Значение и условия должны быть указаны в соответствующем стандарте или изготовителем, или ответственным поставщиком.
Примечание - Номинальное напряжение выражают в вольтах (В).
Источник: ГОСТ Р 54814-2011: Светодиоды и светодиодные модули для общего освещения. Термины и определения оригинал документа
3.4 номинальное напряжение (rated voltage): Напряжение, указанное для прибора производителем.
Источник: ГОСТ Р МЭК 62301-2011: Приборы бытовые электрические. Измерение потребляемой мощности в режиме ожидания оригинал документа
1.3.4 номинальное напряжение (rated voltage): Напряжение или диапазон напряжения, заданное(ый) в соответствии с настоящим стандартом.
Примечание - Если в маркировке на лампе приведен диапазон напряжения, это значит, что возможна эксплуатация ламп при любом значении напряжения в пределах этого диапазона.
Источник: ГОСТ Р 52712-2007: Требования безопасности для ламп накаливания. Часть 1. Лампы накаливания вольфрамовые для бытового и аналогичного общего освещения оригинал документа
3.2 номинальное напряжение (nominal voltage): Номинальное напряжение открытого никель-кадмиевого аккумулятора с газовой рекомбинацией, равное 1,2 В.
Источник: ГОСТ Р МЭК 62259-2007: Аккумуляторы и аккумуляторные батареи, содержащие щелочной и другие некислотные электролиты. Аккумуляторы никель-кадмиевые призматические с газовой рекомбинацией оригинал документа
3.15 номинальное напряжение (nominal voltage): Соответствующее приблизительное значение напряжения, которое используют при проектировании или идентификации элемента, батареи или электрохимической системы.
[IEV 482-03-31:2004]
Источник: ГОСТ Р МЭК 60086-4-2009: Батареи первичные. Часть 4. Безопасность литиевых батарей оригинал документа
3.10 номинальное напряжение (nominal voltage): Соответствующее приблизительное значение напряжения, которое используют для идентификации первичной батареи.
Источник: ГОСТ Р МЭК 60086-5-2009: Батареи первичные. Часть 5. Безопасность батарей с водным электролитом оригинал документа
3.40 номинальное напряжение (rated voltage): Напряжение, установленное для машины изготовителем. При трехфазном питании - напряжение между фазами.
Источник: ГОСТ Р МЭК 60745-1-2009: Машины ручные электрические. Безопасность и методы испытаний. Часть 1. Общие требования оригинал документа
3.2.1 номинальное напряжение (rated voltage): Напряжение, указанное изготовителем для этой машины, или напряжение между фазами (линейное) - при трехфазном питании.
3.11 номинальное напряжение (rated voltage), UH (UN): Напряжение при номинальной частоте, прикладываемое между линейными выводами обмотки.
Источник: ГОСТ Р 54801-2011: Трансформаторы тяговые и реакторы железнодорожного подвижного состава. Основные параметры и методы испытаний оригинал документа
1.3.4 номинальное напряжение (rated voltage): Напряжение или диапазон напряжений, маркируемые на лампе.
Источник: ГОСТ Р 53879-2010: Лампы со встроенными пускорегулирующими аппаратами для общего освещения. Эксплуатационные требования оригинал документа
3.7 номинальное напряжение (design voltage): Объявленное изготовителем напряжение, к которому относятся все характеристики устройства управления лампами и которое должно быть не менее 85 % наибольшего значения диапазона нормируемого напряжения.
Источник: ГОСТ Р МЭК 61347-1-2011: Устройства управления лампами. Часть 1. Общие требования и требования безопасности оригинал документа
3.2 номинальное напряжение (rated voltage): Напряжение или диапазон напряжений, маркируемый на лампе.
Источник: ГОСТ Р МЭК 62560-2011: Лампы светодиодные со встроенным устройством управления для общего освещения на напряжения свыше 50 В. Требования безопасности оригинал документа
3.18 номинальное напряжение (nominal voltage) Un: Напряжение, применяемое для обозначения или идентификации системы электроснабжения.
Источник: ГОСТ Р 51317.4.30-2008: Электрическая энергия. Совместимость технических средств электромагнитная. Методы измерений показателей качества электрической энергии оригинал документа
3.103 номинальное напряжение (rated voltage): Напряжение, указанное изготовителем, для конкретного корпуса.
Источник: ГОСТ Р 50827.5-2009: Коробки и корпусы для электрических аппаратов, устанавливаемые в стационарные электрические установки бытового и аналогичного назначения. Часть 24. Специальные требования к коробкам и корпусам, предназначенным для установки защитных и аналогичных аппаратов с большой рассеиваемой мощностью оригинал документа
3.17 номинальное напряжение (nominal voltage): Номинальное значение напряжения, которое определяет тип источника питания.
Источник: ГОСТ Р 55266-2012: Совместимость технических средств электромагнитная. Оборудование сетей связи. Требования и методы испытаний оригинал документа
3.2.1 номинальное напряжение (rated voltage); Ur:Междуфазное напряжение на выводах генератора при номинальных частоте и мощности.
Примечание - Номинальное напряжение генератора для рабочих и эксплуатационных характеристик устанавливает изготовитель.
Источник: ГОСТ Р 53986-2010: Электроагрегаты генераторные переменного тока с приводом от двигателя внутреннего сгорания. Часть 3. Генераторы переменного тока оригинал документа
3.2.1. номинальное напряжение (rated voltage):
Напряжение, для которого сконструирована установка (или ее часть).
Источник: ГОСТ Р МЭК 60519-1-2005: Безопасность электротермического оборудования. Часть 1. Общие требования оригинал документа
3.1.1 номинальное напряжение (rated voltage): Напряжение, установленное изготовителем для прибора.
Источник: ГОСТ Р 52161.1-2004: Безопасность бытовых и аналогичных электрических приборов. Часть 1. Общие требования оригинал документа
2.3 номинальное напряжение (rated voltage): Стандартное напряжение, на которое рассчитан кабель и которое служит для определения параметров электрических испытаний.
Источник: ГОСТ Р МЭК 60245-1-2006: Кабели с резиновой изоляцией на номинальное напряжение до 450/750 В включительно. Часть 1. Общие требования оригинал документа
2.3 номинальное напряжение (rated voltage): Стандартное напряжение, на которое рассчитан кабель и которое служит для определения параметров электрических испытаний.
Примечание 1 - Номинальное напряжение выражается сочетанием двух значений U0/U, выраженных в вольтах (В):
U0 - среднеквадратическое значение между любой изолированной жилой и «землей» (металлическим покрытием кабеля или окружающей средой);
U - среднеквадратическое значение между любыми двумя фазными жилами многожильного кабеля или системы одножильных кабелей.
В системе переменного тока номинальное напряжение кабеля должно быть не менее номинального напряжения системы, для которой он предназначен.
Это условие относится как к значению U0, так и к значению U.
В системе постоянного тока номинальное напряжение системы должно быть не более полуторного значения номинального напряжения кабеля.
Примечание 2 - Рабочее напряжение системы может постоянно превышать номинальное напряжение такой системы до 10 %. Кабель можно использовать при рабочем напряжении на 10 % выше его номинального напряжения, если последнее по крайней мере равно номинальному напряжению системы.
Источник: ГОСТ Р МЭК 60245-1-2009: Кабели с резиновой изоляцией на номинальное напряжение до 450/750 В включительно. Часть 1. Общие требования оригинал документа
2.3 номинальное напряжение (rated voltage): Стандартное напряжение, на которое рассчитан кабель, служащее для определения параметров электрических испытаний.
Номинальное напряжение выражают сочетанием двух значений - U0/U, выраженных в вольтах:
U0- среднеквадратическое значение между любой изолированной жилой и «землей» (металлическим покрытием кабеля или окружающей средой);
U - среднеквадратическое значение между любыми двумя фазными жилами многожильного кабеля или системы одножильных кабелей.
В системе переменного тока номинальное напряжение кабеля должно быть не менее номинального напряжения системы, для которого он предназначен.
Это требование относится как к значению U0, так и к значению U.
В системе постоянного тока номинальное напряжение системы должно быть не более полуторного значения номинального напряжения кабеля.
Примечание - Рабочее напряжение системы может постоянно превышать номинальное напряжение этой системы до 10 %. Кабель можно использовать при рабочем напряжении, на 10 % превышающем номинальное напряжение, если последнее по крайней мере равно номинальному напряжению системы.
Источник: ГОСТ Р МЭК 60227-1-2009: Кабели с поливинилхлоридной изоляцией на номинальное напряжение до 450/750 В включительно. Часть 1. Общие требования оригинал документа
Русско-английский словарь нормативно-технической терминологии > номинальное напряжение
18 номинальное напряжение изоляции (соединительного устройства)
- rated insulation voltage, (of a connecting device)
напряжение по изоляции
Напряжение, определяемое изготовителем для данного соединителя и его составных частей, с которыми соотносятся испытания на электрическую прочность изоляции, воздушные зазоры и расстояния утечки.
[ ГОСТ Р 51323.1-99]
номинальное напряжение изоляции (соединительного устройства)
-
[IEV number 442-06-39]EN
rated insulation voltage, (of a connecting device)
phase/neutral or phase/phase voltage value assigned to the connecting device by the manufacturer, this device being intended to be used in installations, the voltage supply of which does not exceed the rated insulation voltage of the connecting device itself
NOTE – Rated insulation voltage is always understood to be between live parts and not between live parts and earth (ground).
[IEV number 442-06-39]FR
tension d'isolement assignée (d'un dispositif de connexion)
valeur de la tension phase/neutre ou phase/phase assignée par le constructeur du dispositif de connexion, celui-ci étant prévu pour être utilisé dans des installations dont la tension d'alimentation ne dépasse pas la tension d'isolement assignée du dispositif de connexion lui-même
NOTE – La tension d'isolement assignée est toujours comprise comme la tension entre parties sous tension et non entre parties sous tension et terre.
[IEV number 442-06-39]Тематики
EN
- rated insulation voltage, (of a connecting device)
DE
FR
Русско-английский словарь нормативно-технической терминологии > номинальное напряжение изоляции (соединительного устройства)
19 фазное напряжение
фазное напряжение
Напряжение между линейным и нейтральным проводниками в данной точке электрической цепи переменного тока.
[ ГОСТ Р МЭК 60050-195-2005]
[ ГОСТ Р МЭК 60050-826-2009]EN
line-to-neutral voltage
voltage between a line conductor and the neutral conductor at a given point of an AC circuit
Source: 601-01-30 MOD
[IEV number 195-05-02]FR
tension phase-neutre
tension entre un conducteur de ligne et le conducteur de neutre en un point donné d'un circuit à courant alternatif
Source: 601-01-30 MOD
[IEV number 195-05-02]Недопустимые, нерекомендуемые
Тематики
EN
DE
FR
Русско-английский словарь нормативно-технической терминологии > фазное напряжение
20 защита от неправильного порядка чередования фаз
- protection against phase reversal
- protection against line phase inversion
- phase-reversal protection
- phase sequence protection
защита от неправильного порядка чередования фаз
-
[Интент]Параллельные тексты EN-RU
Phase sequence protection
Where an incorrect phase sequence of the supply voltage can cause a hazardous situation or damage to the machine, protection shall be provided.
NOTE Conditions of use that can lead to an incorrect phase sequence include:
– a machine transferred from one supply to another;
– a mobile machine with a facility for connection to an external power supply.
[IEC 60204-1-2006]Защита от неправильного порядка чередования фаз
Защита от неправильного порядка чередования фаз питающей сети должна быть выполнена в тех случаях, когда неправильное чередование может привести к возникновению опасной ситуации или к повреждению машины.
Примечание. Неправильный порядок чередования фаз сможет возникнуть в процессе эксплуатации в следующих случаях:
- при переключении машины с одного источника питания на другой;
- при подключении мобильной машины, оснащенной собственным средством подключения, к внешнему источнику питания.
[Перевод Интент]When the LTM R controller is connected to an expansion module, phase reversal protection is based on voltage phase sequence before the motor starts, and on current phase sequence after the motor starts.
[Schneider Electric]Если контроллер LTM R соединен с модулем расширения, то защита от неправильного порядка чередования фаз проверяет перед пуском электродвигателя порядок чередование фаз напряжений, а после пуска – порядок чередования фаз токов.
[Перевод Интент]
Тематики
- электротехника, основные понятия
EN
Русско-английский словарь нормативно-технической терминологии > защита от неправильного порядка чередования фаз
СтраницыСм. также в других словарях:
Phase — (f[=a]z), n.; pl. {Phases} (f[=a]z [e^]z). [NL. phasis, Gr. ?, fr. ? to make to appear: cf. F. phase. See {Phenomenon}, {Phantom}, and {Emphasis}.] 1. That which is exhibited to the eye; the appearance which anything manifests, especially any one … The Collaborative International Dictionary of English
Phase-locked loop — PLL redirects here. For other uses, see PLL (disambiguation). A phase locked loop or phase lock loop (PLL) is a control system that generates an output signal whose phase is related to the phase of an input reference signal. It is an electronic… … Wikipedia
Phase converter — A phase converter is a device that converts power provided as single or multiple phases to a different number of phases.The majority of phase converters are used to produce three phase electrical power from a single phase source, thus allowing… … Wikipedia
Voltage multiplier — Villard cascade voltage multiplier. A voltage multiplier is an electrical circuit that converts AC electrical power from a lower voltage to a higher DC voltage, typically by means of a network of capacitors and diodes. Voltage multipliers can be… … Wikipedia
Voltage doubler — A voltage doubler is an electronic circuit which charges capacitors from the input voltage and switches these charges in such a way that, in the ideal case, exactly twice the voltage is produced at the output as at its input. The simplest of… … Wikipedia
phase — phaseless, adj. phasic, phaseal, adj. /fayz/, n., v., phased, phasing. n. 1. any of the major appearances or aspects in which a thing of varying modes or conditions manifests itself to the eye or mind. 2. a stage in a process of change or… … Universalium
Voltage divider — In electronics, a voltage divider (also known as a potential divider) is a simple linear circuit that produces an output voltage ( V out) that is a fraction of its input voltage ( V in). Voltage division refers to the partitioning of a voltage… … Wikipedia
Voltage regulator — A popular three pin 12 V DC voltage regulator IC. A voltage regulator is an electrical regulator designed to automatically maintain a constant voltage level. A voltage regulator may be a simple feed forward design or may include negative feedback … Wikipedia
Voltage — Potential difference redirects here. For other uses, see Potential. Working on high voltage power lines, Pearl Harbor … Wikipedia
Voltage converter — A voltage converter changes the voltage of an electrical power source and is usually combined with other components to create a power supply. The term voltage converter is sometimes used as a generic term for a power supply. A voltage converter… … Wikipedia
Phase-locked Loop — Eine Phasenregelschleife, auch als Phase locked loop (PLL) bezeichnet, ist eine elektronische Schaltungsanordnung, die die Phasenlage und damit zusammenhängend die Frequenz eines veränderbaren Oszillators über einen geschlossenen Regelkreis so… … Deutsch Wikipedia
Перевод: с русского на английский
с английского на русский- С английского на:
- Русский
- С русского на:
- Все языки
- Английский
- Немецкий
- Французский